Standard Test Method for Plutonium Assay by Plutonium (III) Diode Array Spectrophotometry
Automaticky preložený názov:
Štandardná skúšobná metóda pre Plutónium testu podľa plutónia ( III ) Diode Array Spektrofotometria
NORMA vydaná dňa 1.6.2008
Označenie normy: ASTM C1307-02(2008)
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.6.2008
Kód tovaru: NS-10601
Počet strán: 6
Približná hmotnosť: 18 g (0.04 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
diode array spectrophotometry, plutonium assay, spectrophotometry (of plutonium (III)), Chloride analysis--nuclear applications, Diode array spectrophotometry, Nitrate solutions, Plutonium, Plutonium dioxide (powders and pellets), Plutonium (III) diode array spectrophotometry, Spectrophotometry, ICS Number Code 27.120.30 (Fissile materials and nuclear fuel technology), 71.040.50 (Physicochemical methods of analysis)
| Significance and Use | ||||||||||||||||
| p>This test method is designed to determine whether a given material meets the purchaser's specification for plutonium content. | ||||||||||||||||
| 1. Scope | ||||||||||||||||
|
1.1 This test method describes the determination of total plutonium as plutonium(III) in nitrate and chloride solutions. The technique is applicable to solutions of plutonium dioxide powders and pellets (Test Methods C 697), nuclear grade mixed oxides (Test Methods C 698), plutonium metal (Test Methods C 758), and plutonium nitrate solutions (Test Methods C 759). Solid samples are dissolved using the appropriate dissolution techniques described in Practice C 1168. The use of this technique for other plutonium-bearing materials has been reported (1-5), but final determination of applicability must be made by the user. The applicable concentration range for plutonium sample solutions is 10–200 g Pu/L. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||
|