Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board (Includes all amendments And changes 5/29/2013).
Automaticky preložený názov:
Štandardné špecifikácie pre Faced Pevný Cellular polyisokyanurátové dosky tepelnej izolácie
NORMA vydaná dňa 15.12.2012
Označenie normy: ASTM C1289-12a
Poznámka: NEPLATNÁ
Dátum vydania normy: 15.12.2012
Kód tovaru: NS-10506
Počet strán: 7
Približná hmotnosť: 21 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
cellular plastic insulation, cellulosic fiber insulating board, composite foam insulation board, faced foam board, foam plastic insulation, oriented strand board, perlite board, polyiso board, polyisocyanurate, polyisocyanurate foam, polyurethane, polyurethane foam, thermal insulation, waferboard, ICS Number Code 27.220 (Heat recovery. Thermal insulation)
| 1. Scope | ||||||||||||||||||||||||||||||||||||||||||||
|
1.1 This specification covers the general requirements for faced thermal insulation boards composed of rigid cellular polyisocyanurate surfaced with other materials. The insulation boards are intended for use at temperatures between −40 and 200°F (−40 and 93°C). This specification does not cover cryogenic applications. Consult the manufacturer for specific recommendations and properties in cryogenic conditions. For specific applications, the actual temperature limits shall be agreed upon by the manufacturer and the purchaser. 1.2 This standard is intended to apply to rigid cellular polyurethane-modified polyisocyanurate thermal insulation board products that are commercially acceptable as non-structural panels useful in building construction. The term polyisocyanurate encompasses the term polyurethane. For engineering and design purposes, users should follow specific product information provided by board manufacturers regarding physical properties, system design considerations and installation recommendations. 1.3 The use of thermal insulation
materials covered by this specification is typically regulated by
building codes, or other agencies that address fire performance.
Where required, the fire performance of the material shall be
addressed through standard fire test methods established by the
appropriate governing documents.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not
purport to address all of the safety concerns, if any, associated
with its use. It is the responsibility of the user of this standard
to establish appropriate safety and health practices and determine
the applicability of regulatory limitations prior to
use.
|
||||||||||||||||||||||||||||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||||||||||||||||||||||||||||
|
Poskytovanie aktuálnych informácií o legislatívnych predpisoch vyhlásených v Zbierke zákonov od roku 1945.
Aktualizácia 2x v mesiaci !
Chcete vedieť viac informácii ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2026-03-17 (Počet položiek: 2 266 788)
© Copyright 2026 NORMSERVIS s.r.o.