Standard Test Method for Testing of Glass Exudation from AZS Fusion-Cast Refractories
Automaticky preložený názov:
Štandardná skúšobná metóda na skúšanie Glass výron AZS Fusion - Cast Refractories
NORMA vydaná dňa 1.3.2009
Označenie normy: ASTM C1223-09
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.3.2009
Kód tovaru: NS-10103
Počet strán: 4
Približná hmotnosť: 12 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
AZS, casting, exudation, fusion-cast, glass (glass phase), refractories, AZS (alumina-zirconia-silica), Castings, Exudation, Fusion-cast refractories, Glass exudation, ICS Number Code 81.080 (Refractories)
Significance and Use | ||
This test method was developed for use both by manufacturers as a process control tool for the production of AZS fusion-cast refractories, and by glass manufacturers in the selection of refractories and design of glass-melting furnaces. The results may be considered as representative of the potential for an AZS refractory (specifically, in the tested region) to contribute to glass defect formation during the furnace production operation. The procedures and results may be applied to other refractory types or applications (that is, reheat furnace skid rail brick) in which glass exudation is considered to be important. |
||
1. Scope | ||
1.1 This test method covers a procedure for causing the exudation of a glassy phase to the surface of fusion-cast specimens by subjecting them to temperatures corresponding to glass furnace operating temperatures. 1.2 This test method covers a procedure for measuring the exudate as the percent of volume increase of the specimen after cooling. 1.3 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3.1 Exception—The balance required for this test method uses only SI units (Section 6). 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||
2. Referenced Documents | ||
|