Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Guide to Procedures for Calibrating Automatic Pedestrian SNM Monitors
Automaticky preložený názov:
Štandardné sprievodca pre postupy pre kalibráciu automatické peších SNM Monitory
NORMA vydaná dňa 1.6.2011
Označenie normy: ASTM C1189-11
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.6.2011
Kód tovaru: NS-9918
Počet strán: 9
Približná hmotnosť: 27 g (0.06 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
gamma radiation, material control and accountability, neutron radiation, nuclear materials management, radiation detectors, radiation monitors, safeguards, security,Calibration--nuclear analysis instrumentation, Plutonium, Radiation, SNM (special nuclear materials), Uranium, ICS Number Code 17.240 (Radiation measurements)
Significance and Use | ||||||||||
SNM monitors are an effective means to search pedestrians for concealed SNM. Maintaining monitor effectiveness rests on appropriate calibration and adjustment being part of a continuing maintenance program. The significance of this guide for monitor users who must detect SNM is to describe calibration and adjustment procedures for the purpose. The significance of this guide for monitor manufacturers is to describe calibration procedures, particularly for detecting forms of SNM that may not be readily available to them. |
||||||||||
1. Scope | ||||||||||
1.1 This guide covers calibrating the energy response of the radiation detectors and setting the discriminator and alarm thresholds used in automatic pedestrian special nuclear material (SNM) monitors. 1.2 Automatic pedestrian SNM Monitors and their application are described in Guide C1112, which suggests that the monitors be calibrated and tested when installed and that, thereafter, the calibration should be checked and the monitor tested with SNM at three-month intervals. 1.3 Dependable operation of SNM monitors rests, in part, on an effective program to test, calibrate, and maintain them. The procedures and methods described in this guide may help both to achieve dependable operation and obtain timely warning of misoperation. |
||||||||||
2. Referenced Documents | ||||||||||
|
Historická
1.11.2006
Historická
1.6.2012
Historická
1.11.2013
Historická
1.7.2010
Historická
1.11.2011
Historická
1.7.2010
Posledná aktualizácia: 2024-12-23 (Počet položiek: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.