Standard Practice for Joint Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines (Metric)
Automaticky preložený názov:
Štandardná prax pre spoločný preberacie skúšky Inštalovaný prefabrikovaných betónových potrubia kanalizačného potrubia ( metrické )
NORMA vydaná dňa 1.11.2003
Označenie normy: ASTM C1103M-03
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.11.2003
Kód tovaru: NS-9513
Počet strán: 2
Približná hmotnosť: 6 g (0.01 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
acceptance criteria/testing, concrete pipe, field testing-concrete/aggregates, ground-water pressure, joints-concrete applications, pressure testing-concrete pipe, sewer pipe (concrete), joint acceptance testing of installed precast concrete pipe sewer lines, ICS Number Code 23.040.50 (Pipes and fittings of other materials)
| 1. Scope | ||||
|
1.1 This practice covers procedures for testing the joints of installed precast concrete pipe sewer lines, when using either air or water under low pressure to demonstrate the integrity of the joint and the construction procedures. This practice is used for testing 675-mm and larger diameter precast concrete sewer lines utilizing rubber gasket sealed joints. 1.2 This practice is the metric companion of Practice C 1103. Note 1—The owner shall specify the following: who will conduct, observe, and furnish labor, material, and measuring devices and pay for the tests; who is responsible for determining local ground conditions; and whether an air or water test is to be used. Note 2—The user of this practice is advised that test criteria presented in this practice are similar to those in general use. Pipe 600-mm diameter and smaller shall be accepted by infiltration or exfiltration testing utilizing Practice C 969M or by low pressure air testing utilizing Practice C 924M. Pipe greater than 600-mm diameter shall be accepted by infiltration or exfiltration testing utilizing C 969M. Note 3—The user is advised that no correlation has been found between air loss and water leakage. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific safety precautions are given in Section 6. |
||||
| 2. Referenced Documents | ||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2026-05-17 (Počet položiek: 2 278 942)
© Copyright 2026 NORMSERVIS s.r.o.