Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Automaticky preložený názov:
Štandardné testovacie metódy pre teplotu čerstvo zmiešané Hydraulické cementáreň betónu
NORMA vydaná dňa 1.7.2008
Označenie normy: ASTM C1064/C1064M-08
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.7.2008
Kód tovaru: NS-9263
Počet strán: 3
Približná hmotnosť: 9 g (0.02 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
freshly mixed concrete, temperature, temperature measuring device, Portland cement concrete (PCC), Ready-mixed concrete, Structural concrete, Temperature tests, ICS Number Code 91.100.10 (Cement. Gypsum. Lime. Mortar), 91.100.30 (Concrete and concrete products)
| Significance and Use | ||||
|
This test method provides a means for measuring the temperature of freshly mixed concrete. The measured temperature represents the temperature at the time of testing and may not be an indication of the temperature of the freshly mixed concrete at a later time. It may be used to verify conformance to a specified requirement for temperature of concrete. Concrete containing aggregate of a nominal maximum size greater than 3 in. [75 mm] may require up to 20 min for the transfer of heat from aggregate to mortar. (See ACI Committee 207.1R Report. ) |
||||
| 1. Scope | ||||
|
1.1 This test method covers the determination of temperature of freshly mixed hydraulic-cement concrete. 1.2 The values stated in either SI or inch-pound units are to be regarded separately as standard. Within the text, SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.3 The text of this standard references notes and footnotes that provide explanatory information. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure. ) |
||||