Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Practice for Selecting Temperatures for Evaluating and Reporting Thermal Properties of Thermal Insulation
Automaticky preložený názov:
Štandardná prax pre výber teploty pre vyhodnocovanie a podávanie správ tepelné vlastnosti tepelnej izolácie
NORMA vydaná dňa 1.8.2008
Označenie normy: ASTM C1058-03(2008)
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.8.2008
Kód tovaru: NS-9227
Počet strán: 3
Približná hmotnosť: 9 g (0.02 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
building envelope, industrial application, mean test temperature, mechanical process, selecting temperatures, thermal insulation, thermal property, Building envelopes, Industrial applications, Mean test temperature, Mechanical process, Temperature tests--thermal insulation, Thermal analysis (TA)--building materials, Thermal insulating materials, Thermal transmission properties, ICS Number Code 91.120.10 (Thermal insulation of buildings)
Significance and Use | ||||||||||||||||||||||
The various methods for measuring and calculating thermal properties provide data and information for manufacturer's published information, for comparison of related products, and for designers and users to evaluate insulation products for particular applications. For these purposes it is advisable to provide basic data and information produced under standard temperature conditions. Thermal properties of a specimen may change with mean temperature, with temperature difference across the specimens, and with high temperature exposure. Data and information at standard temperatures are necessary for valid comparison of thermal properties. The mean test temperatures to measure thermal properties shall be selected from those listed in Table 1. It is recommended that thermal properties of insulation materials be evaluated over a mean temperature range that represents the intended end use. For this situation, the lowest and greatest mean temperatures should be within 10°C of the maximum and minimum mean temperature of interest. The temperature differences for any chosen mean temperature will depend upon both the thermal insulation application (see appropriate materials specification), the method of evaluation, and the limitations of the apparatus. Temperature differences or relevant temperatue conditions required by ASTM material specifications shall take precedence over those recommended in this practice. Standard conditions are presented where both surfaces are exposed to fixed ambient temperatures that are typical for testing building constructions, both insulated and uninsulated (Table 2). Standard conditions are presented where the temperatures of the two surfaces are fixed and surface coefficients are not considered (Table 3). For conditions where the temperature of only one surface is fixed with the other exposed to fixed ambient temperature, use the mean temperatures of Table 1. These conditions must be stated to describe accurately thermal properties such as thermal conductivity versus mean temperature for thermal insulating materials. Thermal insulations exhibiting inflection points due to the change of state of insulating gases (see Note 2), must be tested at sufficiently small temperature differences between (1) the hot and cold sides and (2) between mean temperatures. The test temperature differences used depend on the vapor pressure versus temperature relationship of the gases involved and the ability of the test apparatus to provide accurate measurements of low temperature differences. Note 2—Certain closed-cell cellular plastic insulations are of this type. |
||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||
1.1 This practice covers standard mean temperatures for reporting thermal properties of thermal insulations, products, and materials, and of related systems and components, both insulated and uninsulated. 1.2 Thermal properties shall be determined as a function of temperature by standard test methods. (Test Methods C 177, C 201, C 236, C 335, C 518, C 745, C 976, C 1114, Guide C 653, and Practice C 687, all in combination with Practice C 1045.) Note 1—Standard referenced materials are needed to span the temperature range of the tests. 1.3 This practice recommends standard conditions for use in testing and evaluating thermal properties as a function of temperature by standard test methods. 1.4 General applications of thermal insulations include: 1.4.1 Building envelopes, 1.4.2 Mechanical systems or processes, and 1.4.3 Building and industrial insulations. 1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. Approximate inch-pound units are provided in the tables. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-05-02 (Počet položiek: 2 896 910)
© Copyright 2024 NORMSERVIS s.r.o.