Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Methods for In-Place Density of Unhardened and Hardened Concrete, Including Roller Compacted Concrete, By Nuclear Methods
Automaticky preložený názov:
Štandardné skúšobné metódy pre In-Place Hustota nevytvrdnutej a zatvrdnutého betónu, vrátane kolieskových hutného betónu, jadrovými metódy
NORMA vydaná dňa 15.11.2013
Označenie normy: ASTM C1040/C1040M-08(2013)
Poznámka: NEPLATNÁ
Dátum vydania normy: 15.11.2013
Kód tovaru: NS-9167
Počet strán: 5
Približná hmotnosť: 15 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
acceptance testing, backscatter measurement, concrete-density, density, direct transmission measurement, gamma radiation, in-place density, nuclear testing , roller-compacted concrete, ICS Number Code 91.100.30 (Concrete and concrete products)
Significance and Use | |||||||||||||||||
3.1 These test methods are useful as rapid, nondestructive techniques for the in-place determination of the density of unhardened concrete. The backscatter test method is also useful for the same purpose on hardened concrete. The fundamental assumptions inherent in the test methods are that Compton scattering is the dominant interaction and that the material under test is homogeneous. 3.2 These test methods are suitable for control and for assisting in acceptance testing during construction, for evaluation of concrete quality subsequent to construction, and for research and development. 3.3 Test results may be affected by
reinforcing steel, by the chemical composition of concrete
constituents, and by sample heterogeneity. The variations resulting
from these influences are minimized by instrument design and by the
user's compliance with appropriate sections of the test procedure.
Results of tests by the backscatter test method may also be
affected by the density of underlying material. The backscatter
test method exhibits spatial bias in that the apparatus's
sensitivity to the material under it decreases with distance from
the surface of the concrete.
1.1 These test methods cover the
determination of the in-place density of unhardened and hardened
concrete, including roller compacted concrete, by gamma radiation.
For notes on the nuclear test see Appendix X1.
1.2 Two test methods are described,
as follows:
Podobné normy: Historická Historická Historická Historická Historická Historická Posledná aktualizácia: 2024-12-23 (Počet položiek: 2 217 157) |