Standard Test Method for Porosity in Metallic Coatings by Humid Sulfur Vapor (""Flowers-of-Sulfur"")
Automaticky preložený názov:
Štandardná skúšobná metóda pre Pórovitosť v kovových povlakov vlhkým síry Vapor ( " Flowers - of - síry " )
NORMA vydaná dňa 1.1.1995
Označenie normy: ASTM B809-95
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.1.1995
Kód tovaru: NS-8226
Počet strán: 5
Približná hmotnosť: 15 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
copper-electrodeposited coatings, porosity-metallic coatings, by humid sulfur vapor ("flowers-of-sulfur"),, test, , Copper alloy, porosity-metallic coatings, by humid sulfur vapor ("flowers-of-sulfur"),, test, , "Flowers-of-sulfur", porosity-metallic coatings, by humid sulfur vapor ("flowers-of-sulfur"),, test, , Metallic coatings, porosity-metallic coatings, by humid sulfur vapor ("flowers-of-sulfur"),, test, , Porosity
| 1. Scope | ||||||||||||||
|
1.1 This standard covers equipment and test methods for determining the porosity of metallic coatings, where the pores penetrate down to a silver, copper, or copper-alloy substrate. 1.2 This test method is suitable for coatings consisting of single or combined layers of any coating that does not significantly tarnish in a reduced sulfur atmosphere, such as gold, nickel, tin, tin-lead, and palladium, or their alloys. 1.3 This test method is designed to determine whether the porosity level is less than or greater than some value which by experience is considered by the user to be acceptable for the intended application. 1.4 Recent reviews of porosity testing and testing methods can be found in the literature. Guide B765 is suitable to assist in the selection of porosity tests for electrodeposits and related metallic coatings. Other porosity test standards are Test Methods B735, B741, B798, and B799. 1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazards statements, see Section 8. |
||||||||||||||
| 2. Referenced Documents | ||||||||||||||
|
Chcete mať istotu o platnosti využívaných predpisov?
Ponúkame Vám riešenie, aby ste mohli používať stále platné (aktuálne) legislatívne predpisy
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2026-05-17 (Počet položiek: 2 278 942)
© Copyright 2026 NORMSERVIS s.r.o.