Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Monitoring of Atmospheric Corrosion Chambers by Quartz Crystal Microbalances
Automaticky preložený názov:
Štandardná skúšobná metóda pre monitorovanie atmosferickej korózii komôr kryštál kremeňa microbalances
NORMA vydaná dňa 10.3.1997
Označenie normy: ASTM B808-97
Poznámka: NEPLATNÁ
Dátum vydania normy: 10.3.1997
Kód tovaru: NS-8222
Počet strán: 3
Približná hmotnosť: 9 g (0.02 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
corrosion monitor, piezoelectric crystals, sensors, thin-film monitor, ICS Number Code 77.060 (Corrosion of metals)
| 1. Scope | ||
|
1.1 This test method monitors the reactivity of a gaseous test environment in which metal surfaces (that is, electrical contacts) and other materials subject to pollutant gas attack, undergo accelerated atmospheric corrosion testing. This test method is applicable to adherent corrosion films whose total corrosion film thickness ranges from a few atomic monolayers to approximately a micrometer. 1.2 The test method provides a dynamic, continuous, in situ, procedure for monitoring the corrosion rate in corrosion chambers; the uniformity of corrosion chambers; and the corrosion rate on different surfaces. Response time of the order of seconds is possible. 1.3 With the proper samples, the quartz crystal microbalance (QCM) test method can also be used to monitor the weight loss from a surface due to the desorption of surface species (that is, reduction of an oxide in a reducing atmosphere). (Alternative names for QCM are quartz crystal oscillator, piezoelectric crystal oscillator, or thin film evaporation monitor.) 1.4 This test method is not sufficient to specify the corrosion process which may be occurring in a chamber, since a variety of pollutant gases and environments may cause similar weight gains. 1.5 This test method is generally not applicable to test environments where solid or liquid particles are deposited on the surface of the quartz crystal. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.7 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. |
||
| 2. Referenced Documents | ||
|
Poskytovanie aktuálnych informácií o legislatívnych predpisoch vyhlásených v Zbierke zákonov od roku 1945.
Aktualizácia 2x v mesiaci !
Chcete vedieť viac informácii ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2026-05-17 (Počet položiek: 2 278 942)
© Copyright 2026 NORMSERVIS s.r.o.