Standard Specification for Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft
Automaticky preložený názov:
Štandardné špecifikácie pre Koncentrický - Lay - plietol medenými vodičmi , Hard , stredne tvrdý , alebo mäkký
NORMA vydaná dňa 10.4.1999
Označenie normy: ASTM B8-99
Poznámka: NEPLATNÁ
Dátum vydania normy: 10.4.1999
Kód tovaru: NS-8176
Počet strán: 8
Približná hmotnosť: 24 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
Concentric-lay-stranded copper electrical conductors, Copper electrical conductors-stranded, Stranded copper conductors, Tin-coated copper wire-electrical conductors, concentric-lay-stranded hard/medium-hard/soft copper conductors, spec.,, Lead alloy-coated copper wire, concentric-lay-stranded hard/medium-hard/softcopper conductors, spec.,,Order Form, ICS Number Code 29.060.20 (Cables)
| 1. Scope | ||||||||||||||||||||||||||
|
1.1 This specification covers bare concentric-lay-stranded conductors made from round copper wires, either uncoated or coated with tin, lead, or lead alloy for general use for electrical purposes. These conductors shall be constructed with a central core surrounded by one or more layers of helically laid wires. Note 1-This specification also permits conductors for use as covered or insulated electrical conductors. Note 2-Sealed conductors, that are intended to prevent longitudinal water propagation and are further covered/insulated, are also permitted within the guidelines of this specification.1.2 For the purposes of this specification, conductors are classified as follows (Explanatory Notes 1 and 2): 1.2.1 Class AA -For bare conductors usually used in overhead lines. 1.2.2 Class A -For conductors to be covered with weather-resistant (weather-proof), slow-burning, materials, and for bare conductors where greater flexibility than is afforded by Class AA is required. 1.2.3 Class B -For conductors to be insulated with various materials such as rubber, paper, varnished cloth, etc., and for the conductors indicated under Class A where greater flexibility is required. 1.2.4 Class C and Class D -For conductors where greater flexibility is required than is provided by Class B conductors. 1.3 The SI values for density are regarded as the standard. For all other properties, the inch-pound values are to be regarded as standard and the SI units may be approximate. |
||||||||||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||||||||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2026-05-15 (Počet položiek: 2 278 685)
© Copyright 2026 NORMSERVIS s.r.o.