Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Specification for Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft
Automaticky preložený názov:
Štandard Specification pre Concentric-Lay-plietol medené vodiče, Hard, Medium-Hard, alebo Soft
NORMA vydaná dňa 1.4.2011
Označenie normy: ASTM B8-11
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.4.2011
Kód tovaru: NS-8175
Počet strán: 8
Približná hmotnosť: 24 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
concentric-lay-stranded copper conductors, concentric-lay-stranded hard, copper conductors, copper conductors for electrical purposes , medium-hard, or soft copper conductors, Concentric-lay-stranded copper electrical conductors, Lead alloy-coated copper wire, Stranded copper electrical conductors--specifications, Tin-coated copper electrical wire, ICS Number Code 29.060.20 (Cables)
| 1. Scope | ||||||||||||||||||||||||||
|
1.1 This specification covers bare concentric-lay-stranded conductors made from round copper wires, either uncoated or coated with tin, lead, or lead alloy for general use for electrical purposes. These conductors shall be constructed with a central core surrounded by one or more layers of helically laid wires. Note 1—This specification also permits conductors for use as covered or insulated electrical conductors. Note 2—Sealed conductors, that are intended to prevent longitudinal water propagation and are further covered/insulated, are also permitted within the guidelines of this specification. 1.2 For the purposes of this specification, conductors are classified as follows (Explanatory Note 1 and Note 2): 1.2.1 Class AA—For bare conductors usually used in overhead lines. 1.2.2 Class A—For conductors to be covered with weather-resistant (weather-proof), slow-burning materials, and for bare conductors where greater flexibility than is afforded by Class AA is required. 1.2.3 Class B—For conductors to be insulated with various materials such as rubber, paper, varnished cloth, and so forth, and for the conductors indicated under Class A where greater flexibility is required. 1.2.4 Class C and Class D—For conductors where greater flexibility is required than is provided by Class B conductors. 1.3 The SI values for density are regarded as the standard. For all other properties, the inch-pound values are to be regarded as standard and the SI units may be approximate. |
||||||||||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||||||||||
|
Poskytovanie aktuálnych informácií o legislatívnych predpisoch vyhlásených v Zbierke zákonov od roku 1945.
Aktualizácia 2x v mesiaci !
Chcete vedieť viac informácii ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2026-05-07 (Počet položiek: 2 276 672)
© Copyright 2026 NORMSERVIS s.r.o.