Standard Test Method for Apparent Density of Free-Flowing Metal Powders Using the Hall Flowmeter Funnel
Automaticky preložený názov:
Štandardná skúšobná metóda pre hustote sypký kovových práškov s využitím do haly Prietokomer Lievik
NORMA vydaná dňa 1.11.2009
Označenie normy: ASTM B212-09
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.11.2009
Kód tovaru: NS-5756
Počet strán: 3
Približná hmotnosť: 9 g (0.02 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
apparent density, Hall flowmeter funnel, metal powders, Density--metal powders (P/M), Free-flowing metal powders, Metal powders, ICS Number Code 77.160 (Powder metallurgy)
| Significance and Use | ||||||||
|
This test method provides a guide for evaluation of an important physical characteristic of a powder known as the apparent density. The measured apparent density bears a relationship to the mass of powder that will fill a fixed volume die cavity. The degree of correlation between the results of this test and the performance of powders during use may vary with each particular application. Note, however, that the presence of moisture, oils, stearic acid, stearates, waxes, and the temperature of the powder mass may alter the physical characteristics of the powder. |
||||||||
| 1. Scope | ||||||||
|
1.1 This test method describes a procedure for determining the apparent density of free-flowing metal powders, and mixed powders; and is suitable for only those powders that will flow unaided through the specified Hall Flowmeter funnel. 1.2 With the exception of density values, for which the g/cm3 unit is the industry standard, the values stated in SI units are to be regarded as the standard. Values in inch-pound units are shown in parentheses and result from conversion in accordance with IEEE/ASTM Standard SI 10. They may be approximate and are only for information. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||
| 2. Referenced Documents | ||||||||
|
Chcete mať istotu o platnosti využívaných predpisov?
Ponúkame Vám riešenie, aby ste mohli používať stále platné (aktuálne) legislatívne predpisy
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2026-05-07 (Počet položiek: 2 276 672)
© Copyright 2026 NORMSERVIS s.r.o.