Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Direct-Current Magnetic Properties of Materials Using the Ballistic Method and Ring Specimens
Automaticky preložený názov:
Štandardná skúšobná metóda pre jednosmerný magnetických vlastností materiálov pomocou balistické metódy a Ring specimens
NORMA vydaná dňa 10.10.1999
Označenie normy: ASTM A596/A596M-95(1999)
Poznámka: NEPLATNÁ
Dátum vydania normy: 10.10.1999
Kód tovaru: NS-3270
Počet strán: 8
Približná hmotnosť: 24 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
Ballistic test, Coercive force, D-c magnetic properties, Direct-current ballistic methods, Epstein cores, Hysteresis effects, Induction, Permeability, Residual induction, Ring test procedures, d-c magnetic properties-materials, (ring/toroidal/link/double-lapped, Epstein cores), using ballistic method and ring specimens, test, ICS Number Code 29.030 (Magnetic materials), 29.100.10 (Magnetic components)
| 1. Scope | ||||||||||||
|
1.1 This test method covers dc ballistic testing for the determination of basic magnetic properties of materials in the form of ring, toroidal, link, double-lapped Epstein cores, or other standard shapes which may be cut, stamped, machined, or ground from cast, compacted, sintered, forged, or rolled materials. It includes tests for normal induction and hysteresis taken under conditions of steep wavefront reversals of the direct-current magnetic field strength. 1.2 This test method shall be used in conjunction with Practice A34. 1.3 This test method is suitable for a testing range from very low magnetic field strength up to 200 or more Oe [15.9 or more kA/m]. The lower limit is determined by integrator sensitivity and the upper limit by heat generation in the magnetizing winding. Special techniques and short duration testing may extend the upper limit of magnetic field strength. 1.4 Testing under this test method is inherently more accurate than other methods. When specified dimensional or shape requirements are observed, the measurements are a good approximation to absolute properties. Test accuracy available is primarily limited by the accuracy of instrumentation. 1.5 This test method permits a choice of test specimen to permit measurement of properties in any desired direction relative to the direction of crystallographic orientation without interference from external yoke systems. 1.6 The symbols and abbreviated definitions used in this test method appear in Fig. 1 and Sections 5, 6, 9 and 10. For the official definitions see Terminology A340. Note that the term flux density used in this document is synonymous with the term magnetic induction. 1.7 The values stated in either customary (absolute (or practical) cgs-emu and inch-pound) units or SI units are to be regarded separately as standard. Within this test method, the SI units are shown in brackets except for the sections concerning calculations where there are separate sections for the respective unit systems. The values stated in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with this method. 1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||
| 2. Referenced Documents | ||||||||||||
|
Posledná aktualizácia: 2026-04-26 (Počet položiek: 2 274 794)
© Copyright 2026 NORMSERVIS s.r.o.