API RP 753, 2nd Edition, January 2024 - Management of Hazards Associated with Location of Process Plant Portable Buildings

General

This recommended practice (RP) provides guidance for managing the risks from process-related explosion, fire, and toxic material release hazards to personnel located in on-site portable buildings.

The document is based on the API 752 guidance for siting evaluations and the referenced documents concerning its technical aspects. For guidance on the evaluation of each hazard type, the reader should reference API 752. This document provides clarifications and alterations where necessary to address portable buildings.

This RP covers:

  • — new and existing light wood trailers;
  • — new and existing portable buildings (other than light wood trailers) intended to be movable and not intended for perpetual use (intended to be used for the life of the structure or life of the plant) in a specific, fixed location.

Annex B provides examples on the coverage of permanent and portable buildings/tents.

This RP was developed for use at refineries, petrochemical and chemical operations, natural gas liquids extraction plants, natural gas liquefaction plants, and other onshore facilities, such as those covered by the Occupational Safety and Health Administration (OSHA) process safety management regulation, 29 CFR 1910.119 [1].

Non-process-related hazards exist that could present risks to building occupants including, but not limited to, fires originating from within the building, structural collapse due to extreme weather/seismic events, and objects falling on or striking the building. These non-process-related hazards are addressed by building design standards and applicable building codes/regulations, and are not within the scope of this RP.

Guiding Principles

API has established guiding principles for building/tent siting, which are used in API 752, API 753, and API 756. These guiding principles apply to all buildings and tents intended for occupancy:

  • 1) locate personnel away from process areas consistent with safe and effective operations;
  • 2) minimize the use of buildings/tents in close proximity to process areas;
  • 3) manage the occupancy of buildings/tents in close proximity to process areas, especially during periods of planned abnormal operation with increased risk including, but not limited to, unit start-up, testing, or planned shutdown operations;
  • 4) design, construct, install, modify, and maintain buildings/tents to protect occupants from the hazards created by explosion, fire, and toxic material release;
  • 5) manage the use of buildings/tents as an integral part of the design, construction, maintenance, operation, and emergency response of a facility.

These guiding principles reflect the concept of the hierarchy of controls. With respect to building hazards, mitigations arranged in a hierarchy, beginning with the most effective, involve:

  • — eliminating either the occupancy or the hazards;
  • — reducing occupancy or the severity of the hazards;
  • — increasing the distance between the occupants and the hazards;
  • — increasing the resistance of the building to the hazards;
  • — administratively managing the occupancy.

Annex F in API 752, 4th Edition provides a summary of a few select events that clarify, illustrate, and emphasize the lessons learned that led to the development of these guiding principles.

Relationship with API 752 and API 756

New and existing permanent buildings are covered by API 752 [2].

New and existing portable buildings (other than light wood trailers) intended for perpetual use in a specific, fixed location are covered by API 752.

New and existing tents are covered by API 756 [3].

Table B.1 provides examples on the coverage of permanent and portable buildings/tents.

All references in this RP to API 752 and API 756 are to the 4th and 2nd Editions, respectively, which published concurrently with API 753.

Odporúčame:

EviZak - všetky zákony vrátane ich evidencie na jednom mieste

Poskytovanie aktuálnych informácií o legislatívnych predpisoch vyhlásených v Zbierke zákonov od roku 1945.
Aktualizácia 2x v mesiaci !

Chcete vedieť viac informácii ? Pozrite sa na túto stránku.




Cookies Cookies

Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.

Súhlas môžete odmietnuť tu.

Tu máte možnosť prispôsobiť si nastavenia súborov cookies v súlade s vlastnými preferenciami.

Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov.