Norma API RP 14F-ed.6 1.10.2018 náhľad

API RP 14F-ed.6

Recommended Practice for Design, Installation, and Maintenance of Electrical Systems for Fixed and Floating Offshore Petroleum Facilities for Unclassified and Class I, Division 1, and Division 2 Locations



NORMA vydaná dňa 1.10.2018


Jazyk
Prevedenie
DostupnosťSKLADOM
Cena219.70 bez DPH
219.70

Informácie o norme:

Označenie normy: API RP 14F-ed.6
Dátum vydania normy: 1.10.2018
Kód tovaru: NS-1140008
Počet strán: 189
Približná hmotnosť: 598 g (1.32 libier)
Krajina: Americká technická norma
Kategória: Technické normy API

Anotácia textu normy API RP 14F-ed.6 :

API RP 14F, 6th Edition, October 2018 - Recommended Practice for Design, Installation, and Maintenance of Electrical Systems for Fixed and Floating Offshore Petroleum Facilities for Unclassified and Class I, Division 1, and Division 2 Locations

General

This document recommends minimum requirements and guidelines for the design, installation, and maintenance of electrical systems on fixed and floating petroleum facilities located offshore. For facilities classified as Zone 0, Zone 1, or Zone 2, reference API RP 14FZ, Recommended Practice for Design, Installation, and Maintenance of Electrical Systems for Fixed and Floating Offshore Petroleum Facilities for Unclassified and Class I, Zone 0, Zone 1, and Zone 2 Locations. These facilities include drilling, producing, and pipeline transportation facilities associated with oil and gas exploration and production. This recommended practice is not applicable to mobile offshore drilling units (MODUs) without production facilities. This document is intended to bring together in one place a brief description of basic desirable electrical practices for offshore electrical systems. The recommended practices contained herein recognize that special electrical considerations exist for offshore petroleum facilities. These include the following:

  • a) the inherent electrical shock possibility presented by the marine environment and steel decks;
  • b) space limitations that require that equipment be installed in or near hazardous (classified) locations;
  • c) the corrosive marine environment;
  • d) motion and buoyancy concerns associated with floating facilities.

This recommended practice applies to both permanent and temporary electrical installations. The guidelines presented herein should provide a high level of electrical safety when used in conjunction with welldefined area classifications. This recommended practice emphasizes safe practices for hazardous (classified) locations on offshore petroleum facilities but does not include guidelines for classification of areas; for guidance on the classification of areas refer to API RP 500.

Applicability of the National Electrical Code

Electrical systems for offshore petroleum facilities shall be designed and installed in accordance with the National Electrical Code (NEC), 2017 edition, except where specific departures are noted.

Odporúčame:

Aktualizácia technických noriem

Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.

Chcete vedieť viac informácií ? Pozrite sa na túto stránku.




Cookies Cookies

Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.

Súhlas môžete odmietnuť tu.

Tu máte možnosť prispôsobiť si nastavenia súborov cookies v súlade s vlastnými preferenciami.

Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov.