Preconditioned Air (PCA) Unit Air Quality, Humidity Management, and Cabin Connection
NORMA vydaná dňa 1.9.2026
Designation standards: SAE ARP6986
Publication date standards: 1.9.2026
Country: American technical standard
Kategória: Technické normy SAE
The provisions of this SAE Aerospace Recommended Practice (ARP) cover minimum performance requirements and design parameters for preconditioned air (PCA) devices supplying air to the aircraft cabin. It identifies the need for interim and future performance improvement for ground equipment delivery systems, to meet industry requirements for reducing airborne compounds or particulates (“source types”) in the aircraft cabin and flight deck. This ARP will guide SAE, IATA, airline operators, and airframe and PCA manufacturers to meet new requirements. This ARP defines:
Minimum performance and maintenance requirements for filtration, hose assemblies, operations, and maintenance.
Level of humidity supplied by the ground equipment to the aircraft cabin.
Minimum performance and maintenance requirements for digital communication of cabin parameters between the cabin and the PCA.
Installation of the sensor unit within the aircraft cabin. The data collected by these sensors is not intended to assess impacts on aircraft occupant health and shall not be used to make a finding of airworthiness.
SUBFILE: Aerospace
TYPE OF DOCUMENT: Aerospace Standard