ASTM B173-17

Standard Specification for Rope-Lay-Stranded Copper Conductors Having Concentric-Stranded Members, for Electrical Conductors

NORMA vydaná dňa 1.4.2017

Anglicky -
PDF - okamžité stiahnutie (58.70 EUR)

Anglicky -
PDF + redline - ihneď (70.40 EUR)

Anglicky -
Tlačené (58.70 EUR)

Anglicky -
Tlač + redline (70.40 EUR)


Prečo Redline?

Redline predstavuje rýchly a jednoduchý spôsob ako porovnať všetky zmeny medzi aktuálne platnou normou a predchádzajúcou verziou.

Vďaka redline sa okamžite dozviete o:

Ušetrite si čas aj starosti!

Vďaka Redline už nebudete musieť strácať čas zisťovaním, čo sa v novej norme zmenilo. Redline Vám ušetrí čas a zaručí, že sa o zmenách v norme dozviete.

Cena

Ak si zvolíte možnosť "Platná norma + Redline", potom dostanete oba dokumenty! A čo je najlepšie, cena Platné normy + Redline je len o niečo málo vyššia ako cena samostatnej platné normy.

Zobraziť ukážku Redline

The information about the standard:

Designation standards: ASTM B173-17
Publication date standards: 1.4.2017
The number of pages: 7
Approximate weight : 21 g (0.05 lbs)
Country: American technical standard
Kategória: Technické normy ASTM

Annotation of standard text ASTM B173-17 :

This specification covers bare rope-lay-stranded conductors having concentric-stranded members made from round copper wires, either uncoated or coated with tin, lead, or lead-alloy for use as electrical conductors. Coated wires shall include only those wires with finished diameters and densities substantially equal to the respective diameters and densities of uncoated wires. The rope-lay-stranded copper conductors under this specification are classified either as Class G or Class H. Requirements for joint construction (by soldering, brazing, or welding), lay length, and strand construction are detailed. Tests for the electrical properties of wires composing conductors made from soft or annealed copper wire, bare or coated, shall be made before stranding, while tests for the physical properties (such as elongation) may be made upon the wires before stranding or upon wires removed from the completed stranded conductors, but need not be made upon both. Elongation tests to determine compliance shall not be made on the conductor as a unit. If a tinning, lead-coating, or lead-alloy-coating test is required, it shall be made on the wires prior to stranding. The method of calculating mass, cross-sections and electrical resistance, and the prescribed density of copper to be taken for calculations are given.


Keywords:
copper electrical conductor, electrical conductor´copper, rope-lay-stranded copper conductors, stranded copper conductor,, ICS Number Code 29.240.20 (Power transmission and distribution lines)