NORMSERVIS s.r.o.

ASTM C844-26

Standard Specification for Application of Gypsum Base to Receive Gypsum Veneer Plaster

NORMA vydaná dňa 1.5.2026

Anglicky -
Online zabezpečené PDF (61.80 EUR)

Anglicky -
Norma a Redline - Online zabezpečené PDF (74.20 EUR)

Anglicky -
Tlačené (61.80 EUR)

Anglicky -
Tlač + redline (74.20 EUR)


Prečo Redline?

Redline predstavuje rýchly a jednoduchý spôsob ako porovnať všetky zmeny medzi aktuálne platnou normou a predchádzajúcou verziou.

Vďaka redline sa okamžite dozviete o:

Ušetrite si čas aj starosti!

Vďaka Redline už nebudete musieť strácať čas zisťovaním, čo sa v novej norme zmenilo. Redline Vám ušetrí čas a zaručí, že sa o zmenách v norme dozviete.

Cena

Ak si zvolíte možnosť "Platná norma + Redline", potom dostanete oba dokumenty! A čo je najlepšie, cena Platné normy + Redline je len o niečo málo vyššia ako cena samostatnej platné normy.

Zobraziť ukážku Redline

The information about the standard:

Designation standards: ASTM C844-26
Publication date standards: 1.5.2026
The number of pages: 9
Approximate weight : 27 g (0.06 lbs)
Country: American technical standard
Kategória: Technické normy ASTM

Annotation of standard text ASTM C844-26 :

This specification covers the minimum requirements for, and methods of, application of gypsum veneer base for gypsum veneer plasters. Details of construction for a specific assembly to achieve the required fire resistance shall be obtained from reports of fire-resistance tests, engineering evaluations, or listings from recognized fire testing laboratories. The materials shall be classified as follows: gypsum base for veneer plasters; gypsum backing board for coreboard; special fire-retardant gypsum base; foil-backed gypsum base; gypsum veneer plaster; nails; non-load bearing steel; load bearing steel; steel framing, non-load bearing; accessories; adhesives; steel framing load bearing; and wood framing. The maximum spacing of framing members for singly gypsum base construction shall be not more than then specified values. Application of gypsum base, single-ply gypsum base, adhesive-mechanical fastener, foil-backed gypsum base, two-ply gypsum base, and application over existing surfaces shall be indicated. Solid gypsum base partitions shall include face ply, core, and runners. Direct adhesive application shall be used only on interior masonry or concrete walls above grade, or inside of exterior masonry cavity walls. Gypsum base application over steel framing and furring shall include screw application, framing space, and screw spacing. Gypsum base applied to the soffit of arches shall be carefully bent into place and shall conform to the specified values of bending radii.


Keywords:
electric heat cable, gypsum, gypsum base, veneer plastic,, ICS Number Code 91.100.10 (Cement. Gypsum. Lime. Mortar)