NORMSERVIS s.r.o.

ASTM C655M-19a

Standard Specification for Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer Pipe (Metric) (Includes all amendments and changes 8/5/2019).

NORMA vydaná dňa 15.7.2019

Anglicky -
PDF - okamžité stiahnutie (58.10 EUR)

Anglicky -
PDF + redline - ihneď (69.70 EUR)

Anglicky -
Tlačené (58.10 EUR)

Anglicky -
Tlač + redline (69.70 EUR)


Prečo Redline?

Redline predstavuje rýchly a jednoduchý spôsob ako porovnať všetky zmeny medzi aktuálne platnou normou a predchádzajúcou verziou.

Vďaka redline sa okamžite dozviete o:

Ušetrite si čas aj starosti!

Vďaka Redline už nebudete musieť strácať čas zisťovaním, čo sa v novej norme zmenilo. Redline Vám ušetrí čas a zaručí, že sa o zmenách v norme dozviete.

Cena

Ak si zvolíte možnosť "Platná norma + Redline", potom dostanete oba dokumenty! A čo je najlepšie, cena Platné normy + Redline je len o niečo málo vyššia ako cena samostatnej platné normy.

Zobraziť ukážku Redline

Informácie o norme:

Označenie normy: ASTM C655M-19a
Dátum vydania normy: 15.7.2019
Počet strán: 7
Približná hmotnosť: 21 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM

Anotácia textu normy ASTM C655M-19a :

This specification covers reinforced concrete pipe, D-load culvert, storm drain, and sewer pipe for the conveyance of sewage, industrial wastes, and storm water. The numerical values in this specification are not presented in inch-pound units, but rather, in metric or SI units only. The reinforced concrete shall consist of cementitious materials, mineral aggregates, and water, in which steel has been embedded in such a manner that the steel and concrete act together. The combination of cementitious materials used in the concrete shall be only one of the following: Portland cement, Portland blast furnace slag cement, slag modified Portland cement, Portland pozzolan cement, a combination of Portland cement and fly ash, a combination of Portland cement and ground granulated blast-furnace slag, or a combination of Portland cement, ground granulated blast furnace slag, and fly ash. Reinforcement shall conform to the standard specification. Physical requirements shall conform to the design strength designation of the pipe during load test. The aggregates shall be sized, graded, proportioned, and mixed with such proportions of cementitious materials and water as will produce a homogeneous concrete mixture of such quality that the pipe shall conform to the test and design requirements of this specification. The strength of the pipe shall not be adversely affected by the splice. Compression tests for determining concrete compressive strength shall be allowed to be made on either concrete cylinders or on cores drilled from the pipe. Pipe shall be repaired, if necessary, because of imperfections in manufacture, damage during handling, or pipe that have been cored for testing.


Keywords:
concrete pipe´reinforced, culvert, D load, sewer pipe, storm drains, three edge bearing strength,, ICS Number Code 23.040.50 (Pipes and fittings of other materials)