Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
ASTM Volume 03.03 - Nondestructive Testing (E94 - E2373)
PUBLIKÁCIE vydaná dňa 1.10.2019
Dostupnosť | Vypredané |
Cena | NA OTÁZKU bez DPH |
NA OTÁZKU |
Označenie: ASTM Volume 03.03 - Nondestructive Testing (E94 - E2373)
Počet strán: 1386
Približná hmotnosť: 4189 g (9.24 libier)
Dátum vydania: 1.10.2019
Krajina: Americká publikácia
Volumes 03.03 and 03.04 provide standards on nondestructive testing of engineering materials, structures and assemblies to detect flaws and characterize the properties of materials. NDT methods cover: Reference Radiological Images, Radiology (Neutron, X, Gamma), Digital Imaging, Acoustic Emission, Liquid Penetrant and Magnetic Particle, Electromagnetic, Leak Testing, and Ultrasonic.
C1331-18 | Standard Practice for Measuring Ultrasonic Velocity in Advanced Ceramics with Broadband Pulse-Echo Cross-Correlation Method |
C1332-18 | Standard Practice for Measurement of Ultrasonic Attenuation Coefficients of Advanced Ceramics by Pulse-Echo Contact Technique |
E94/E94M-17 | Standard Guide for Radiographic Examination Using Industrial Radiographic Film |
E114-15 | Standard Practice for Ultrasonic Pulse-Echo Straight-Beam Contact Testing |
E125-63(2018) | Standard Reference Photographs for Magnetic Particle Indications on Ferrous Castings |
E127-15 | Standard Practice for Fabrication and Control of Aluminum Alloy Ultrasonic Standard Reference Blocks |
E155-15 | Standard Reference Radiographs for Inspection of Aluminum and Magnesium Castings |
E164-19 | Standard Practice for Contact Ultrasonic Testing of Weldments |
E165/E165M-18 | Standard Practice for Liquid Penetrant Testing for General Industry |
E186-15 | Standard Reference Radiographs for Heavy-Walled (2 to 412 in. (50.8 to 114 mm)) Steel Castings |
E192-15 | Standard Reference Radiographs of Investment Steel Castings for Aerospace Applications |
E213-14e1 | Standard Practice for Ultrasonic Testing of Metal Pipe and Tubing |
E215-16 | Standard Practice for Standardizing Equipment and Electromagnetic Examination of Seamless Aluminum-Alloy Tube |
E242-15(2020) | Standard Reference Radiographs for Appearances of Radiographic Images as Certain Parameters are Changed |
E243-18 | Standard Practice for Electromagnetic (Eddy Current) Examination of Copper and Copper-Alloy Tubes |
E272-15 | Standard Reference Radiographs for High-Strength Copper-Base and Nickel-Copper Alloy Castings |
E273-15 | Standard Practice for Ultrasonic Testing of the Weld Zone of Welded Pipe and Tubing |
E280-15(2019)e1 | Standard Reference Radiographs for Heavy-Walled (412 to 12 in. (114 to 305 mm)) Steel Castings |
E309-16 | Standard Practice for Eddy Current Examination of Steel Tubular Products Using Magnetic Saturation |
E310-15(2019)e1 | Standard Reference Radiographs for Tin Bronze Castings |
E317-16 | Standard Practice for Evaluating Performance Characteristics of Ultrasonic Pulse-Echo Testing Instruments and Systems without the Use of Electronic Measurement Instruments |
E376-19 | Standard Practice for Measuring Coating Thickness by Magnetic-Field or Eddy Current (Electromagnetic) Testing Methods |
E390-15 | Standard Reference Radiographs for Steel Fusion Welds |
E426-16 | Standard Practice for Electromagnetic (Eddy Current) Examination of Seamless and Welded Tubular Products, Titanium, Austenitic Stainless Steel and Similar Alloys |
E428-08(2013) | Standard Practice for Fabrication and Control of Metal, Other than Aluminum, Reference Blocks Used in Ultrasonic Testing |
E431-96(2016) | Standard Guide to Interpretation of Radiographs of Semiconductors and Related Devices |
E432-91(2017)e1 | Standard Guide for Selection of a Leak Testing Method |
E433-71(2018) | Standard Reference Photographs for Liquid Penetrant Inspection |
E446-15 | Standard Reference Radiographs for Steel Castings Up to 2 in. (50.8 mm) in Thickness |
E493/E493M-11(2017) | Standard Practice for Leaks Using the Mass Spectrometer Leak Detector in the Inside-Out Testing Mode |
E494-15 | Standard Practice for Measuring Ultrasonic Velocity in Materials |
E498/E498M-11(2017) | Standard Practice for Leaks Using the Mass Spectrometer Leak Detector or Residual Gas Analyzer in the Tracer Probe Mode |
E499/E499M-11(2017) | Standard Practice for Leaks Using the Mass Spectrometer Leak Detector in the Detector Probe Mode |
E505-15 | Standard Reference Radiographs for Inspection of Aluminum and Magnesium Die Castings |
E515-11(2018) | Standard Practice for Leaks Using Bubble Emission Techniques |
E543-15 | Standard Specification for Agencies Performing Nondestructive Testing |
E545-19 | Standard Test Method for Determining Image Quality in Direct Thermal Neutron Radiographic Examination |
E566-19 | Standard Practice for Electromagnetic (Eddy Current/Magnetic Induction) Sorting of Ferrous Metals |
E569/E569M-13 | Standard Practice for Acoustic Emission Monitoring of Structures During Controlled Stimulation |
E570-15e1 | Standard Practice for Flux Leakage Examination of Ferromagnetic Steel Tubular Products |
E571-19 | Standard Practice for Electromagnetic (Eddy-Current) Examination of Nickel and Nickel Alloy Tubular Products |
E587-15(2020) | Standard Practice for Ultrasonic Angle-Beam Contact Testing |
E592-15 | Standard Guide to Obtainable ASTM Equivalent Penetrameter Sensitivity for Radiography of Steel Plates 14 to 2 in. (6 to 51 mm) Thick with X-Rays and 1 to 6 in. (25 to 152 mm) Thick with Cobalt-60 |
E650/E650M-17 | Standard Guide for Mounting Piezoelectric Acoustic Emission Sensors |
E664/E664M-15(2020)e1 | Standard Practice for the Measurement of the Apparent Attenuation of Longitudinal Ultrasonic Waves by Immersion Method |
E689-15 | Standard Reference Radiographs for Ductile Iron Castings |
E690-15(2020) | Standard Practice for In Situ Electromagnetic (Eddy Current) Examination of Nonmagnetic Heat Exchanger Tubes |
E703-14 | Standard Practice for Electromagnetic (Eddy Current) Sorting of Nonferrous Metals |
E709-15 | Standard Guide for Magnetic Particle Testing |
E746-18 | Standard Practice for Determining Relative Image Quality Response of Industrial Radiographic Imaging Systems |
E747-18 | Standard Practice for Design, Manufacture and Material Grouping Classification of Wire Image Quality Indicators (IQI) Used for Radiology |
E748-19 | Standard Guide for Thermal Neutron Radiography of Materials |
E749/E749M-17 | Standard Practice for Acoustic Emission Monitoring During Continuous Welding |
E750-15(2020) | Standard Practice for Characterizing Acoustic Emission Instrumentation |
E751/E751M-17 | Standard Practice for Acoustic Emission Monitoring During Resistance Spot-Welding |
E797/E797M-15 | Standard Practice for Measuring Thickness by Manual Ultrasonic Pulse-Echo Contact Method |
E801-16 | Standard Practice for Controlling Quality of Radiographic Examination of Electronic Devices |
E802-15 | Standard Reference Radiographs for Gray Iron Castings Up to 412 in. (114 mm) in Thickness |
E803-17 | Standard Test Method for Determining the L/D?Ratio of Neutron Radiography Beams |
E908-98(2018) | Standard Practice for Calibrating Gaseous Reference Leaks |
E976-15 | Standard Guide for Determining the Reproducibility of Acoustic Emission Sensor Response |
E977-05(2014) | Standard Practice for Thermoelectric Sorting of Electrically Conductive Materials |
E999-15 | Standard Guide for Controlling the Quality of Industrial Radiographic Film Processing |
E1000-16 | Standard Guide for Radioscopy |
E1001-16 | Standard Practice for Detection and Evaluation of Discontinuities by the Immersed Pulse-Echo Ultrasonic Method Using Longitudinal Waves |
E1002-11(2018) | Standard Practice for Leaks Using Ultrasonics |
E1003-13(2018) | Standard Practice for Hydrostatic Leak Testing |
E1004-17 | Standard Test Method for Determining Electrical Conductivity Using the Electromagnetic (Eddy Current) Method |
E1025-18 | Standard Practice for Design, Manufacture, and Material Grouping Classification of Hole-Type Image Quality Indicators (IQI) Used for Radiography |
E1030/E1030M-15 | Standard Practice for Radiographic Examination of Metallic Castings |
E1032-19 | Standard Practice for Radiographic Examination of Weldments Using Industrial X-Ray Film |
E1033-13 | Standard Practice for Electromagnetic (Eddy Current) Examination of Type F-Continuously Welded (CW) Ferromagnetic Pipe and Tubing Above the Curie Temperature |
E1065/E1065M-14 | Standard Guide for Evaluating Characteristics of Ultrasonic Search Units |
E1066/E1066M-19 | Standard Practice for Ammonia Colorimetric Leak Testing |
E1067/E1067M-18 | Standard Practice for Acoustic Emission Examination of Fiberglass Reinforced Plastic Resin (FRP) Tanks/Vessels |
E1079-16 | Standard Practice for Calibration of Transmission Densitometers |
E1106-12(2017) | Standard Test Method for Primary Calibration of Acoustic Emission Sensors |
E1114-09(2014) | Standard Test Method for Determining the Size of Iridium-192 Industrial Radiographic Sources |
E1118/E1118M-16(2020) | Standard Practice for Acoustic Emission Examination of Reinforced Thermosetting Resin Pipe (RTRP) |
E1135-19 | Standard Test Method for Comparing the Brightness of Fluorescent Penetrants |
E1139/E1139M-17 | Standard Practice for Continuous Monitoring of Acoustic Emission from Metal Pressure Boundaries |
E1158-14 | Standard Guide for Material Selection and Fabrication of Reference Blocks for the Pulsed Longitudinal Wave Ultrasonic Testing of Metal and Metal Alloy Production Material |
E1161-09(2014) | Standard Practice for Radiologic Examination of Semiconductors and Electronic Components |
E1165-12(2017) | Standard Test Method for Measurement of Focal Spots of Industrial X-Ray Tubes by Pinhole Imaging |
E1208-16 | Standard Practice for Fluorescent Liquid Penetrant Testing Using the Lipophilic Post-Emulsification Process |
E1209-18 | Standard Practice for Fluorescent Liquid Penetrant Testing Using the Water-Washable Process |
E1210-16 | Standard Practice for Fluorescent Liquid Penetrant Testing Using the Hydrophilic Post-Emulsification Process |
E1211/E1211M-17 | Standard Practice for Leak Detection and Location Using Surface-Mounted Acoustic Emission Sensors |
E1212-17 | Standard Practice for Establishing Quality Management Systems for Nondestructive Testing Agencies |
E1213-14(2018) | Standard Practice for Minimum Resolvable Temperature Difference for Thermal Imaging Systems |
E1219-16 | Standard Practice for Fluorescent Liquid Penetrant Testing Using the Solvent-Removable Process |
E1220-16 | Standard Practice for Visible Penetrant Testing Using Solvent-Removable Process |
E1254-13(2018) | Standard Guide for Storage of Radiographs and Unexposed Industrial Radiographic Films |
E1255-16 | Standard Practice for Radioscopy |
E1311-14(2018) | Standard Practice for Minimum Detectable Temperature Difference for Thermal Imaging Systems |
E1312-18 | Standard Practice for Electromagnetic (Eddy Current) Examination of Ferromagnetic Cylindrical Bar Product Above the Curie Temperature |
E1316-19a | Standard Terminology for Nondestructive Examinations |
E1320-15 | Standard Reference Radiographs for Titanium Castings |
E1324-16 | Standard Guide for Measuring Some Electronic Characteristics of Ultrasonic Testing Instruments |
E1359-17 | Standard Guide for Auditing and Evaluating Capabilities of Nondestructive Testing Agencies |
E1390-12(2016) | Standard Specification for Illuminators Used for Viewing Industrial Radiographs |
E1411-16 | Standard Practice for Qualification of Radioscopic Systems |
E1416-16a | Standard Practice for Radioscopic Examination of Weldments |
E1417/E1417M-16 | Standard Practice for Liquid Penetrant Testing |
E1418-16 | Standard Practice for Visible Penetrant Testing Using the Water-Washable Process |
E1419/E1419M-15a(2020) | Standard Practice for Examination of Seamless, Gas-Filled, Pressure Vessels Using Acoustic Emission |
E1441-19 | Standard Guide for Computed Tomography (CT) |
E1444/E1444M-16e1 | Standard Practice for Magnetic Particle Testing |
E1453-14 | Standard Guide for Storage of Magnetic Tape Media that Contains Analog or Digital Radioscopic Data |
E1475-13(2018) | Standard Guide for Data Fields for Computerized Transfer of Digital Radiological Examination Data |
E1476-04(2014) | Standard Guide for Metals Identification, Grade Verification, and Sorting |
E1495/E1495M-17 | Standard Guide for Acousto-Ultrasonic Assessment of Composites, Laminates, and Bonded Joints |
E1543-14(2018) | Standard Practice for Noise Equivalent Temperature Difference of Thermal Imaging Systems |
E1570-19 | Standard Practice for Fan Beam Computed Tomographic (CT) Examination |
E1571-11(2016)e1 | Standard Practice for Electromagnetic Examination of Ferromagnetic Steel Wire Rope |
E1603/E1603M-11(2017) | Standard Practice for Leakage Measurement Using the Mass Spectrometer Leak Detector or Residual Gas Analyzer in the Hood Mode |
E1606-15 | Standard Practice for Electromagnetic (Eddy Current) Examination of Copper and Aluminum Redraw Rod for Electrical Purposes |
E1629-12(2020) | Standard Practice for Determining the Impedance of Absolute Eddy-Current Probes |
E1647-16 | Standard Practice for Determining Contrast Sensitivity in Radiology |
E1648-15 | Standard Reference Radiographs for Examination of Aluminum Fusion Welds |
E1672-12 | Standard Guide for Computed Tomography (CT) System Selection |
E1695-95(2013) | Standard Test Method for Measurement of Computed Tomography (CT) System Performance |
E1734-16a | Standard Practice for Radioscopic Examination of Castings |
E1735-07(2014) | Standard Test Method for Determining Relative Image Quality of Industrial Radiographic Film Exposed to X-Radiation from 4 to 25 MeV |
E1736-15 | Standard Practice for Acousto-Ultrasonic Assessment of Filament-Wound Pressure Vessels |
E1742/E1742M-18 | Standard Practice for Radiographic Examination |
E1774-17 | Standard Guide for Electromagnetic Acoustic Transducers (EMATs) |
E1781/E1781M-19 | Standard Practice for Secondary Calibration of Acoustic Emission Sensors |
E1814-14 | Standard Practice for Computed Tomographic (CT) Examination of Castings |
E1815-18 | Standard Test Method for Classification of Film Systems for Industrial Radiography |
E1816-18 | Standard Practice for Measuring thickness by Pulse-Echo Electromagnetic Acoustic Transducer (EMAT) Methods |
E1817-08(2014) | Standard Practice for Controlling Quality of Radiological Examination by Using Representative Quality Indicators (RQIs) |
E1862-14(2018) | Standard Practice for Measuring and Compensating for Reflected Temperature Using Infrared Imaging Radiometers |
E1888/E1888M-17 | Standard Practice for Acoustic Emission Examination of Pressurized Containers Made of Fiberglass Reinforced Plastic with Balsa Wood Cores |
E1897-14(2018) | Standard Practice for Measuring and Compensating for Transmittance of an Attenuating Medium Using Infrared Imaging Radiometers |
E1901-18 | Standard Guide for Detection and Evaluation of Discontinuities by Contact Pulse-Echo Straight-Beam Ultrasonic Methods |
E1930/E1930M-17 | Standard Practice for Examination of Liquid-Filled Atmospheric and Low-Pressure Metal Storage Tanks Using Acoustic Emission |
E1931-16 | Standard Guide for Non-computed X-Ray Compton Scatter Tomography |
E1932-12(2017) | Standard Guide for Acoustic Emission Examination of Small Parts |
E1933-14(2018) | Standard Practice for Measuring and Compensating for Emissivity Using Infrared Imaging Radiometers |
E1934-99a(2018) | Standard Guide for Examining Electrical and Mechanical Equipment with Infrared Thermography |
E1935-97(2013) | Standard Test Method for Calibrating and Measuring CT Density |
E1936-15 | Standard Reference Radiograph for Evaluating the Performance of Radiographic Digitization Systems |
E1955-04(2014) | Standard Radiographic Examination for Soundness of Welds in Steel by Comparison to Graded ASTM Reference Radiographs |
E1961-16 | Standard Practice for Mechanized Ultrasonic Testing of Girth Welds Using Zonal Discrimination with Focused Search Units |
E1962-14 | Standard Practice for Ultrasonic Surface Testing Using Electromagnetic Acoustic Transducer (EMAT) Techniques |
E2001-18 | Standard Guide for Resonant Ultrasound Spectroscopy for Defect Detection in Both Metallic and Non-metallic Parts |
E2002-15 | Standard Practice for Determining Total Image Unsharpness and Basic Spatial Resolution in Radiography and Radioscopy |
E2003-10(2014) | Standard Practice for Fabrication of the Neutron Radiographic Beam Purity Indicators |
E2007-10(2016) | Standard Guide for Computed Radiography |
E2023-19 | Standard Practice for Fabrication of Neutron Radiographic Sensitivity Indicators |
E2024/E2024M-11(2019) | Standard Practice for Atmospheric Leaks Using a Thermal Conductivity Leak Detector |
E2033-17 | Standard Practice for Radiographic Examination Using Computed Radiography (Photostimulable Luminescence Method) |
E2075/E2075M-15(2020) | Standard Practice for Verifying the Consistency of AE-Sensor Response Using an Acrylic Rod |
E2076/E2076M-15 | Standard Practice for Examination of Fiberglass Reinforced Plastic Fan Blades Using Acoustic Emission |
E2096/E2096M-16 | Standard Practice for In Situ Examination of Ferromagnetic Heat-Exchanger Tubes Using Remote Field Testing |
E2104-15 | Standard Practice for Radiographic Examination of Advanced Aero and Turbine Materials and Components |
E2191/E2191M-16 | Standard Practice for Examination of Gas-Filled Filament-Wound Composite Pressure Vessels Using Acoustic Emission |
E2192-13(2018) | Standard Guide for Planar Flaw Height Sizing by Ultrasonics |
E2223-13(2018)e1 | Standard Practice for Examination of Seamless, Gas-Filled, Steel Pressure Vessels Using Angle Beam Ultrasonics |
E2261/E2261M-17 | Standard Practice for Examination of Welds Using the Alternating Current Field Measurement Technique |
E2297-15 | Standard Guide for Use of UV-A and Visible Light Sources and Meters used in the Liquid Penetrant and Magnetic Particle Methods |
E2337/E2337M-10(2015) | Standard Guide for Mutual Inductance Bridge Applications for Wall Thickness Determinations in Boiler Tubing |
E2338-17 | Standard Practice for Characterization of Coatings Using Conformable Eddy Current Sensors without Coating Reference Standards |
E2339-15 | Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) |
E2373/E2373M-14 | Standard Practice for Use of the Ultrasonic Time of Flight Diffraction (TOFD) Technique |
Posledná aktualizácia: 2024-05-17 (Počet položiek: 2 902 148)