Standard Practice for Evaluation of Pre-saturated or Impregnated Towelettes for Hard Surface Disinfection
Automaticky preložený názov:
Štandardné praktiky pre hodnotenie Pre- nasýtených alebo impregnované obrúsky na tvrdom povrchu Dezinfekcia
NORMA vydaná dňa 1.10.2015
Označenie normy: ASTM E2362-15
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.10.2015
Kód tovaru: NS-618401
Počet strán: 7
Približná hmotnosť: 21 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
Efficacy, glass carriers, Mycobacterium bovis , pre-saturated, Pseudomonas aeruginosa , Salmonella enterica , Staphylococcus aureus , towelette, Trichophyton mentagrophytes,, ICS Number Code 71.100.35 (Chemicals for industrial and domestic desinfection purposes)
Significance and Use | ||||
5.1 This practice may be used to determine if a pre-saturated or impregnated towelette demonstrates antimicrobial effectiveness as a disinfectant on hard surfaces. This practice provides survivor results in the form of a qualitative endpoint (growth positive versus growth negative). The results generated by following this practice do not provide for specific quantitative reductions. |
||||
1. Scope | ||||
1.1 This practice is designed to evaluate the antimicrobial activity of pre-saturated or impregnated towelettes when used as a hard surface disinfectant. 1.2 It is the responsibility of the investigator to determine whether Good Laboratory Practices (GLP’s) are required and to follow them when appropriate. 1.3 This practice should be performed only by those trained in microbiological techniques. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 Appropriate modifications to the practice may be required when testing organisms not specified herein. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use. |
||||
2. Referenced Documents | ||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-05-03 (Počet položiek: 2 896 946)
© Copyright 2024 NORMSERVIS s.r.o.