Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Determination of Fuel Filter Blocking Potential of Biodiesel (B100) Blend Stock by Cold Soak Filtration Test (CSFT) (Includes all amendments And changes 11/10/2017).
Automaticky preložený názov:
Štandardná skúšobná metóda pre stanovenie palivového filtra Blokovanie potenciálu (B100), zmes akcie od prechladnutiu filtrácie test (CSFT)
NORMA vydaná dňa 1.11.2012
Označenie normy: ASTM D7501-12a
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.11.2012
Kód tovaru: NS-38625
Počet strán: 6
Približná hmotnosť: 18 g (0.04 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
biodiesel, biodiesel blend, diesel fuel, filter blocking potential, glass fiber filter, laboratory filtration, low temperature operability, middle distillate fuel, ICS Number Code 75.160.20 (Liquid fuels)
Significance and Use | ||||||||
5.1 Some substances that are soluble or appear to be soluble in biodiesel (B100) at room temperature will, upon cooling to temperatures above the cloud point or standing at room temperature for extended periods, come out of solution. This phenomenon has been observed in both B100 and BXX blends. These substances can cause filter plugging. This method provides an accelerated means of assessing the presence of these substances in B100 and their propensity to plug filters. 5.1.1 B100 biodiesel fuels that give short filtration times are expected to give satisfactory operation of BXX blends at least down to the cloud point of the biodiesel blends. 5.2 The test method can be used in specifications as a means of controlling levels of minor filter plugging components in biodiesel and biodiesel blends. |
||||||||
1. Scope | ||||||||
1.1 This test method covers the determination by filtration time after cold soak of the suitability for a biodiesel (B100) blend stock that meets all other requirements of Specification D6751 and has a cloud point below 20°C (68°F) to provide adequate low temperature operability performance to at least the cloud point of the finished blend. 1.2 The formal precision of this test method is included in 13.1 on Precision. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||
2. Referenced Documents | ||||||||
|
Historická
1.5.2014
Historická
1.11.2012
Historická
15.2.2010
Historická
1.5.2014
Historická
1.11.2012
Historická
1.5.2010
Chcete mať istotu o platnosti využívaných predpisov?
Ponúkame Vám riešenie, aby ste mohli používať stále platné (aktuálne) legislatívne predpisy
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-11-22 (Počet položiek: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.