Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Practice for On-Line Determination of Cation Conductivity in High Purity Water (Includes all amendments and changes 2/9/2017).
Automaticky preložený názov:
Bežná prax pre on-line Stanovenie katiónov vodivosti vo vode s vysokou čistotou
NORMA vydaná dňa 15.2.2016
Označenie normy: ASTM D6504-11(2016)e1
Dátum vydania normy: 15.2.2016
Kód tovaru: NS-632824
Počet strán: 6
Približná hmotnosť: 18 g (0.04 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
boiler cycle chemistry, cation conductivity, on-line, process measurement,, ICS Number Code 13.060.60 (Examination of water for physical properties)
Significance and Use | ||||||||||||||||||
5.1 Cation conductivity provides one of the most sensitive and dependable on-line means of detecting anionic contamination in the boiler/steam cycle, such as chlorides, sulfates, nitrates, bicarbonates, and organic acids, such as formic and acetic. 5.2 High sensitivity is provided by intentionally eliminating the pH adjusting treatment chemical(s), for example, ammonia and amines, from the sample and converting remaining salt contaminants into their acid forms which are approximately three times as conductive. 5.3 Guidelines on cation conductivity limits for various cycle chemistry and boiler types have been established by EPRI 5.4 The sample effluent from the cation exchange column also may be used, and in some cases is preferred, for ion chromatography or other anion measurements. |
||||||||||||||||||
1. Scope | ||||||||||||||||||
1.1 This practice describes continuous sample conditioning by hydrogen ion exchange and measurement by electrolytic conductivity. It is commonly known as cation conductivity measurement in the power industry although it is actually an indication of anion contamination in high purity water samples. Measurements are typically in a range less than 1 μS/cm. 1.2 The actual conductivity measurements are made using Test Method D5391. 1.3 This practice does not provide for separate determination of dissolved carbon dioxide. Refer to Test Method D4519. 1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-04-30 (Počet položiek: 2 896 468)
© Copyright 2024 NORMSERVIS s.r.o.