Standard Test Methods for Thermoplastic Insulations and Jackets for Wire and Cable (Includes all amendments And changes 11/18/2020).
Automaticky preložený názov:
Štandardné skúšobné metódy pre Termoplastické izolácií a bundy pre káble a vodiče
NORMA vydaná dňa 1.11.2013
Označenie normy: ASTM D2633-13a
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.11.2013
Kód tovaru: NS-20967
Počet strán: 15
Približná hmotnosť: 45 g (0.10 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
accelerated water absorption, cold bend test, dielectric strength retention, elongation, heat aging, heat distortion, heat shock, insulation resistance, oil immersion, partial discharge extinction level, surface resistivity, tensile strength, thermoplastic insulation, thermoplastic jacket, thickness, track resistance, U-bend discharge, vertical flame test, voltage withstand tests, ICS Number Code 29.035.20 (Plastic and rubber insulating materials)
Significance and Use | ||||||||||||||||||||||||||||||||||||
6.1 Physical tests, properly interpreted, provide information with regard to the physical properties of the insulation or jacket. The physical test values give an approximation of how the insulation will physically perform in its service life. Physical tests provide useful data for research and development, engineering design, quality control, and acceptance or rejection under specifications. |
||||||||||||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||||||||||||
1.1 These test methods cover procedures for the testing of thermoplastic insulations and jackets used on insulated wire and cable. To determine the test to be made on the particular insulation or jacket compound, refer to the product specification for that type. These test methods do not apply to the class of products known as flexible cords. The electrical tests on insulation and water-absorption tests do not apply to the class of products having a separator between the conductor and the insulation. 1.2 These test methods pertain to insulation or jacket material for electrical wires and cables. In many instances the insulation or jacket material cannot be tested unless it has been formed around a conductor or cable. Therefore, tests are done on insulated or jacketed wire or cable in these test methods solely to determine the relevant property of the insulation or jacket material and not to test the conductor or completed cable. 1.3 Whenever two sets of values are presented, in different units, the values in the first set are the standard, while those in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.5 The procedures appear in the following sections:
|
||||||||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||||||||
|
Historická
1.10.2010
Historická
1.4.2014
Historická
1.3.2014
Historická
1.8.2011
Historická
1.10.2010
Historická
1.9.2013
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-04-28 (Počet položiek: 2 896 137)
© Copyright 2024 NORMSERVIS s.r.o.