Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Methods for Nonvolatile Matter in Halogenated Organic Solvents and Their Admixtures
Automaticky preložený názov:
Štandardné testovacie metódy pre energeticky nezávislé hmoty v halogénované organické rozpúšťadlá a ich Prísady
NORMA vydaná dňa 1.2.2016
Označenie normy: ASTM D2109-01(2016)
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.2.2016
Kód tovaru: NS-636006
Počet strán: 4
Približná hmotnosť: 12 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
halogenated organic solvents, nonvolatile matter, nonvolatile residue, residue on evaporation ,, ICS Number Code 71.080.20 (Halogenated hydrocarbons)
Significance and Use |
3.1 Nonvolatile matter in solvents can adversely affect their cleaning properties. These test methods can be used to control soil contamination in the boiling solvent, which if allowed to become too high, can decrease the stability of the solvent. 3.2 These test methods can be used to establish manufacturing and purchasing specifications. |
1. Scope |
1.1 These test methods cover the determination of nonvolatile matter in halogenated organic solvents and admixtures. 1.2 Five test methods are covered, as follows: 1.2.1 Test Method A—For halogenated organic solvents or admixtures having less than 50 ppm nonvolatile matter; or where precision better than ±10 ppm is required. 1.2.2 Test Method B—For halogenated organic solvents or admixtures having more than 50 ppm nonvolatile matter or where precision of ±0.001 % (10 ppm) is satisfactory. 1.2.3 Test Method C—For low-boiling halogenated organic solvents or their admixtures (for example, methylene chloride, trichlorotrifluoroethane) that may superheat and cause bumping while evaporating to dryness with steam. A precision of greater than ±10 ppm can be attained. 1.2.4 Test Method D—For rapid measurement of nonvolatile matter in halogenated organic solvents and their admixtures and where precision better than ±10 ppm is required. 1.2.5 Test Method E—For halogenated organic solvents or admixtures and where precision better than ±10 ppm is required. 1.3 The values stated in SI units are to be regarded as standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
Posledná aktualizácia: 2024-05-12 (Počet položiek: 2 898 605)
© Copyright 2024 NORMSERVIS s.r.o.