Standard Test Method for Slump of Hydraulic-Cement Concrete (Includes all amendments And changes 7/14/2020).
Automaticky preložený názov:
Štandardná testovacia metóda pre prepadu Hydraulické cementáreň betónu
NORMA vydaná dňa 15.12.2015
Označenie normy: ASTM C143/C143M-15a
Poznámka: NEPLATNÁ
Dátum vydania normy: 15.12.2015
Kód tovaru: NS-632696
Počet strán: 4
Približná hmotnosť: 12 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
concrete, concrete slump, cone, consistency, plasticity, slump, workability ,, ICS Number Code 91.100.30 (Concrete and concrete products)
Significance and Use | ||||||||||||||
4.1 This test method is intended to provide the user with a procedure to determine slump of plastic hydraulic-cement concretes. Note 1: This test method was originally developed to provide a
technique to monitor the consistency of unhardened concrete. Under
laboratory conditions, with strict control of all concrete
materials, the slump is generally found to increase proportionally
with the water content of a given concrete mixture, and thus to be
inversely related to concrete strength. Under field conditions,
however, such a strength relationship is not clearly and
consistently shown. Care should therefore be taken in relating
slump results obtained under field conditions to
strength.
4.2 This test method is considered applicable to plastic concrete having coarse aggregate up to 11/2 in. [37.5 mm] in size. If the coarse aggregate is larger than 11/2 in. [37.5 mm] in size, the test method is applicable when it is performed on the fraction of concrete passing a 11/2-in. [37.5-mm] sieve, with the larger aggregate being removed in accordance with the section titled “Additional Procedure for Large Maximum Size Aggregate Concrete” in Practice C172. 4.3 This test method is not considered applicable to non-plastic and non-cohesive concrete. Note 2: Concretes having slumps less than
1/2 in. [15 mm] may not be adequately
plastic and concretes having slumps greater than about 9 in. [230
mm] may not be adequately cohesive for this test to have
significance. Caution should be exercised in interpreting such
results.
|
||||||||||||||
1. Scope | ||||||||||||||
1.1 This test method covers determination of slump of hydraulic-cement concrete, both in the laboratory and in the field. 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.3 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.2) |
||||||||||||||
2. Referenced Documents | ||||||||||||||
|